This is the settings menu page.
Levelling
Would you like the Auto Levelling to function with Headland Management System (HMS)?
How much should the dead-band be delayed? Recommended value is 2 secs.
Would you like the Auto Levelling to stop and start when the HMS is activated?
Calibration can be carried out by pressing ‘Calibration’
Levelling Calibration
Once the machine is on a level surface, manually operate the joystick until you are happy that the machine is level, then press OK.
Steering
Should the wheels be set straight automatically while working in HMS?
Would you like the wheels to be operated by moving the central joystick left/right or up/down?
What should the dead band be for auto centring? Recommended value is 0.
Calibration can be carried out by pressing ‘Calibration’
Steering Calibration
First, press Reset. Then, turn the wheels from left to right in full lock, then position the wheels so that they are straight. Then press OK.
Depth Control
Set the working depth. You can change this value also on the Main Operations page.
The recommended delay for the auto depth sensitivity is 2 seconds.
If you would like to have auto depth activated in HMS, select ON.
The recommended value for flow control when moving the joystick is 7.
The recommended value for flow control when auto depth is activated 3 or 4.
Advanced Depth Control
Advanced Settings allows you to change the type of depth control sensor. This is only to be used on machine which have been adapted. Each sensor requires pre-calibration by a ScanStone engineer.
Elevator
If the machine is equipped with an elevator, it will appear on the Settings Menu.
When you have entered the Elevator screen, you can see if the elevator is connected or disconnected.
Once the elevator has been mounted on the machine, you can connect it by pressing the ‘Connect’ soft key. Make sure that the rear lift is fully down, and then select ‘yes’.
Once the elevator is connected, the following notification will appear:
This will be explained more thoroughly in the Main Operations section.
Display
The language and brightness can be changed in the Display Settings page. The recommended value for brightness is 8.
HMS 1
In the first HMS page, you can change the delay time of lifting and lowering the disks.
If you prefer the scrubber web to stop automatically when HMS is activated, select ON and the time delay.
If you prefer the scrubber web to resume automatically when HMS is activated, select ON and the time delay.
The right arrow soft key will take you to the second HMS page.
HMS 2
If you prefer the cross conveyor to be switched off when HMS is activated, select ON and the time delay.
If you prefer the cross conveyor to be switched on when HMS is activated, select ON and the time delay.
If you prefer the cross conveyor to be reversed when HMS is activated, select ON and the time delay.